PSB950/1050 PT bar for tunnel construction soil anchor/rock bolt
Through these environmental considerations, stress rod and post-tensioning techniques not only increase the strength and durability of building structures but also contribute to more sustainable and environmentally friendly building practices.
Post tensioning is a technique for reinforcing concrete. Post-tensioning tendons, which are prestressing steel cables inside plastic ducts or sleeves, are positioned in the forms before the concrete is placed. Afterwards, once the concrete has gained strength but before the service loads are applied, the cables are pulled tight, or tensioned, and anchored against the outer edges of the concrete.
Longitudinal Resistance: External tendons are commonly installed in the longitudinal direction to increase a structure’s resistance against traffic loads. This is particularly useful for bridges and large slabs where heavy loads are a concern.
Nominal Diameter | Diameter | H | B | L | Nominal Section | Nominal Weight | |
Dv | Dh | ||||||
mm | mm | mm | mm | mm | mm | mm2 | kg/m |
15 | 15 | 15 | 1.0 | 4.5 | 10 | 176 | 1.47 |
18 | 18 | 18 | 1.0 | 4.0 | 10 | 254.5 | 2.11 |
20 | 20 | 20 | 1.3 | 4.8 | 10 | 314 | 2.47 |
25 | 25 | 25 | 1.6 | 6.0 | 12 | 490.9 | 4.10 |
32 | 32 | 32 | 2.0 | 7.0 | 16 | 804.2 | 6.65 |
36 | 36 | 36 | 2.5 | 8.0 | 18 | 1018 | 8.41 |
40 | 40 | 40 | 3.0 | 8.0 | 20 | 1256.6 | 10.34 |
50 | 50 | 50 | 3.0 | 9.0 | 24 | 1963.5 | 16.28 |
60 | 60 | 60 | 3.0 | 10.0 | 22 | 2827 | 23.26 |
63.5 | 63 | 63.5 | 3.0 | 12.0 | 22 | 3167 | 26.20 |
65 | 65 | 65 | 3.0 | 12.0 | 22 | 3318 | 27.470 |
70 | 70 | 70 | 3.0 | 12.0 | 22 | 3848 | 31.8 |
75 | 75 | 75 | 3.0 | 12.0 | 22 | 4418 | 36.9 |
Grade500/630 | NominalDia. | CrossSection | YieldStrength | TensileStrength | YieldLoad | UltimateLoad | Elongation | NominalWeight |
mm | mm2 | >=Mpa | >=Mpa | KN | KN | A/% | KG/m | |
20 | 314 | 500 | 630 | 157 | 198 | 10 | 2.47 | |
25 | 491 | 500 | 630 | 246 | 309 | 10 | 4.1 | |
28 | 615 | 500 | 630 | 308 | 387 | 10 | 4.83 |